Products >>> EPS
|
|
EPS is for the purpose of offering the electric power to meet an emergency for the lighting in house, office building, hospital, and exhibition etc. Normally, when the urgent situation happens, like fire, electric power cut-off, EPS as a reserve power, can supply the electric power to the light in order to ensure staff evacuate from the buildings to the safe place.
Above parameters are all matched with the China national standard of GB-17945, and the products have passed the proof-test of China National Center for Quality Supervision and Test for Fire Electronic Products.
|
| ITEM |
1KW |
2KW |
COMMENTS |
| INPUT |
| *Input voltage |
|
|
|
| - phase |
single phase with ground |
|
| -Input voltage range |
220Vac -20%/+20% |
|
| -input power factor |
90% |
Nominal input voltage and full load |
| -EPS starting threshold |
220Vac -20%/+20% |
|
| *Input frequency |
|
|
| -EPS starting threshold |
50HZ +5%/-5% |
|
| *Generator |
yes |
|
| *Input current |
|
|
| - max rms current |
8.1A |
15.2A |
Line on low & load with 100%R |
| *Input protection |
|
|
| - protect |
Fuse and Breaker protection |
|
| OUTPUT |
| *Output power |
|
|
| -VA/Watt |
1.4KVA/1KW |
2.8KVA/2KW |
|
| -Output power factor |
0.7 |
|
| *Output voltage |
220V |
|
| -waveform |
Sine Wave |
|
| -voltage distortion |
<3% |
full line load |
| -transient response |
±4%Max |
from 100% to 20% or from 20% |
|
|
to 100% R load(except for battery |
|
|
mode 100% to 20% is 9%Max.) |
| -current crest ratio |
3:1 max |
|
| *Output frequency range |
|
|
| -battery mode |
50HZ +0.5%/-0.5% |
|
| -line mode |
same as mains |
|
| *Efficiency |
|
|
| -line mode |
>98% |
nominal 100% line load |
| -battery mode |
>85% |
nominal 100% line load |
| *Over load capability |
|
|
| -line mode |
>120% bypass |
Line load |
| -battery mode |
>120% turn off |
Line load |
| *Short circuit protection |
|
|
| -line mode |
Auto shutdown |
output short |
| -battery mode |
Auto shutdown |
output short |
| CHARGING & DISCHARGING |
| *External Battery |
|
|
| (Default allocation) |
|
|
| -battery voltage |
96vdc |
96vdc |
|
| -backup time |
Depend on the capacity of external battery |
|
| -prealarm |
93Vdc |
|
| *Protection |
|
|
| -auto shutdown |
86Vdc±3% |
|
| -overvoltage battery |
115Vdc |
battery :12V |
| *battery to replace |
|
|
| warning |
|
|
| -during inverter test |
93Vdc |
battery:12V |
| -during weekly batterytest |
83Vdc |
battery:12V |
| *Charging |
|
|
| -voltage level |
220Vdc±0.5% |
floating value |
| -recharge time |
8~10 Hrs over 90% capacity |
after 100% line load discharged. |
| -DC current limit level |
by test data satisfy charge time |
|
| * Charger |
yes |
|
| -input voltage range |
|
|
| -output voltage |
220Vdc±0.5% |
|
| -initial charging current |
10A |
|
| *Indicators |
|
|
| -led display indicating |
In voltage,Bat voltage,Bypass,Inv,EPS fault |
|
| -lcd display indicating |
In/out voltage,Frequency,Batterry boltage |
|
|
Power rate and EPS status |
|
| *Control |
|
|
| -alarm silence |
yes |
|
| -DC power start, |
yes |
|
| after the first ac start up |
|
|
|
| TRANSFER |
|
|
| -Full automatic, |
yes |
|
| touch-pad control |
|
|
| -Full system self |
yes |
|
| test on power up |
|
|
| *Audio alarm |
|
|
| battary mode |
beep/4 Sec |
|
| battery low |
beep/0.5 Sec |
|
| EPS fault |
continuous |
full R load / no load |
| over load |
beep/0.5 Sec |
dependent on battery spec. |
| ENVIRONMENT |
| *Operation |
|
|
| temperature |
0 ℃ ~40 ℃ |
|
| humidity |
20%~90% |
|
| * Acoustic noise |
|
|
|
<50DB at meter |
|
| *storage temperature |
-25 ℃ - 55 ℃ |
|
| *humidity |
20% - 90% |
|
| MECHANICAL FEATURES |
| *Size |
The size of the EPS must be processed as the customer's request. |
| -W x H x D (mm) |
|
|
|
|
| -Weight:(Kg) |
|
|
|
|
| ITEM |
3KW |
4KW |
5KW |
6KW |
7KW |
COMMENTS |
| INPUT |
| *Input voltage |
|
|
| - phase |
single phase with ground |
|
| -Input voltage range |
220Vac -20%/+20% |
|
| -input power factor |
90% |
Nominal input voltage and full load |
| -EPS starting threshold |
220Vac -20%/+20% |
|
| *Input frequency |
|
|
| -EPS starting threshold |
50HZ +5%/-5% |
|
| *Generator |
yes |
|
| *Input current |
|
|
| - max rms current |
21.2A |
28A |
34.5A |
40.5A |
46.5A |
Line on low & load with 100%R |
| *Input protection |
|
|
| - protect |
Fuse and Breaker protection |
|
| OUTPUT |
| *Output power |
|
|
| -VA/Watt |
4.3KVA/3KW |
5.7KVA/4KW |
7.2KVA/5KW |
8.6KVA/6KW |
10KVA/7KW |
|
| -Output power factor |
0.7 |
|
| *Output voltage |
220V |
|
| -waveform |
Sine Wave |
|
| -voltage distortion |
<3% |
full line load |
| -transient response |
±4%Max |
from 100% to 20% or from 20% |
|
|
to 100% R load(except for battery |
|
|
mode 100% to 20% is 9%Max.) |
| -current crest ratio |
3:1 max |
|
| *Output frequency range |
|
|
| -battery mode |
50HZ +0.5%/-0.5% |
|
| -line mode |
same as mains |
|
| *Efficiency |
|
|
| -line mode |
>98% |
nominal 100% line load |
| -battery mode |
>85% |
nominal 100% line load |
| *Over load capability |
|
|
| -line mode |
>120% bypass |
Line load |
| -battery mode |
>120% turn off |
Line load |
| *Short circuit protection |
|
|
| -line mode |
Auto shutdown |
output short |
| -battery mode |
Auto shutdown |
output short |
| CHARGING & DISCHARGING |
| *External Battery |
|
|
| (Default allocation) |
|
|
| -battery voltage |
192vdc |
192vdc |
192vdc |
192vdc |
192vdc |
|
| -backup time |
Depend on the capacity of external battery |
|
| -prealarm |
176Vdc |
|
| *Protection |
|
|
| -auto shutdown |
168Vdc±3% |
|
| -overvoltage battery |
240Vdc |
battery :12V |
| *battery to replace |
|
|
| warning |
|
|
| -during inverter test |
176Vdc |
battery:12V |
| -during weekly batterytest |
144Vdc |
battery:12V |
| *Charging |
|
|
| -voltage level |
220Vdc±0.5% |
floating value |
| -recharge time |
8~10 Hrs over 90% capacity |
after 100% line load discharged. |
| -DC current limit level |
by test data satisfy charge time |
|
| * Charger |
yes |
|
| -input voltage range |
|
|
| -output voltage |
220Vdc±0.5% |
|
| -initial charging current |
10A |
|
| *Indicators |
|
|
| -led display indicating |
In voltage,Bat voltage,Bypass,Inv,EPS fault |
|
| -lcd display indicating |
In/out voltage,Frequency,Batterry boltage |
|
|
Power rate and EPS status |
|
| *Control |
|
|
| -alarm silence |
yes |
|
| -DC power start, |
yes |
|
| after the first ac start up |
|
|
|
| TRANSFER |
|
|
| -Full automatic, |
yes |
|
| touch-pad control |
|
|
| -Full system self |
yes |
|
| test on power up |
|
|
| *Audio alarm |
|
|
| battary mode |
beep/4 Sec |
|
| battery low |
beep/0.5 Sec |
|
| EPS fault |
continuous |
full R load / no load |
| over load |
beep/0.5 Sec |
dependent on battery spec. |
| ENVIRONMENT |
| *Operation |
|
|
| temperature |
0 ℃ ~40 ℃ |
|
| humidity |
20%~90% |
|
| * Acoustic noise |
<50DB at meter |
|
| *storage temperature |
-25 ℃ - 55 ℃ |
|
| *humidity |
20% - 90% |
|
| MECHANICAL FEATURES |
| *Size |
The size of the EPS must be processed as customer's request. |
| -WxHxD(mm) |
|
|
|
|
|
| -Weight:(Kg) |
|
|
|
|
|
Next page
|
|
|